yjv22-10kv銅芯電纜,yjv22-3*240每米重量及價格 交聯聚絕緣電力電纜是采用化學或物理,使聚分子由線型分子結構轉變為三維網狀結構,由熱塑性的聚變成熱固性的交聯聚,從而了聚的耐老化性能、機械性能和耐能力,并保持了優良的電氣性能。
交聯聚絕緣電力電纜導體的允許長期高溫為90攝氏度,較低絕緣電纜、聚氯絕緣電纜和聚絕緣電纜高,且具有重量輕、結構簡單、使用方便、耐化學腐蝕和敷設不受落差等優點。
26/35KV電力電纜,18/30KV交聯電纜,12/20KVYJV電纜,8.7/15KVYJV22電纜線,6/10KV鋁芯交聯電纜線,3.6/6KVYJLV單芯電纜
中低壓交聯電纜產品 Standard
本產品按GB12706《額定電壓35V及以下銅芯、鋁芯塑料絕緣電力電纜》生產,同時還可根據用戶需要按電工會推薦IEC、英國、德國及美國生產。
The product is manufactured according to the standard of《GB12706 or IEC、BS、DIN and ICEA upon request.
適用范圍 Applications
本產品適用于工頻額定電壓3.6/6kv~26/35kv輸配電線路作配送電能子用。
The product is suitable for use in power transmission and distribution lines with rated power frequency voltage 3.6/6kv~26/35kv.
使用特性 Operating characteristics
· 工頻額定電壓U0/U為3.6/6kv~26/35kv。
Rated power-frepuency voltage U0/U: 3.6/6kv~26/35kv.
· 電纜導體的高允許工作溫度:90℃。
Max.admissible operating temperature of the conductor:90℃.
· 短路時(長時間不超過5s)電纜導體的高溫度不超過2500C。
Max. short-circurt temperature of conductor shall not exceed 2500C.
(5s maximum duration)
· 電纜敷設時溫度應不低于00C。
The ambient temperature under installation should not below 00C.
· 電纜彎曲半徑:三芯電纜不小于電纜外徑15倍;單芯電纜不小于電纜外徑20倍。
The bending radius of a single-core cable should not less than 20 times of the cable diameter.
The bending radius of a single-core cable should not less than 15 times of the cable diameter.
yjv22-10kv銅芯電纜,yjv22-3*240每米重量及價格電纜額定電壓的選擇 Voltage designation
纜的額定電壓應適合于電纜的運行狀況,用U0/U(Um)kv表示。
U0-電纜設計用的導體對地或金屬屏蔽之間的額定工頻電壓;
U-電纜設計用的導體間的額定工頻電壓;
Um-設備可承受的“高電壓”的大值。
The rated voltage of the cable for a given applixation shall be suitable for the operating conditions
in the system in which the cable is used,and is expressed in the form of U0/U(Um)kv
Where:
U0-The rated power-frequency voltage between conductors and earth metallic screen ,for which the cable designed;
U - The rated power-frequency voltage between conductos, for which the cable designed;
Um- The maximum value of the“highest system voltage”for which the equipment may beused.
· 三相用電纜的U0值推薦如下表:
The values of U0 recommened for cable to be used in three-phase systems are listed below:
|
U kv
|
U m kv
|
U 0 * kv
|
A 和 B 類 System categories A and B
|
C 類 Systems categories C
|
6
|
7.2
|
3.6
|
6
|
10
|
12
|
6
|
8.7
|
15
|
17.5
|
8.7
|
12
|
20
|
24
|
12
|
18
|
30
|
36
|
18
|
-
|
35
|
40.5
|
21
|
26
|
|
A類──該類任何一相導體與地和接地導體時,能在1min內與分離
B類──該類僅包括單相接地故障短時運行的條件,接地故障時間應不超過1h, 但在任何情況下,長不超過8h每年接地故障總時間不超過125h;
C類──不屬于A類、B類的。
System category A──This category comprises those systems in which any phase conductor that comes in contact with earth or an earth conductor. is disconnected from the system within 1 min.
System category B ──This category comprises those system which,under faultconditions,are operated,are operated for ashorttimewith one phase earthed.This period should not exceed 1 h..Fora longer period, not exceeding 8h on any occasion, can be tolerated.The total duration of earth faults in any year should not exceed 125h.
System categeory C──This category comprises all systems which do not fall into A and B
電纜的型號Type of cable
|
型號 Type
|
名稱 Designation
|
適用范圍 Application
|
YJV
|
銅芯交聯聚絕緣氯護套電力電纜 Copper conductor,XLPE insulated and PVC sheathed power cable
|
室內、及電纜溝等場所,不能承受機械外力。單芯電纜不允許敷設在磁性管道中。 For laying indoors 、 intunnel or cable trench,unable to bear external mechan-icalforces.Single-core cable in magnetic duct is not permissible
|
YJLY
|
鋁芯交聯聚絕緣護套電力電纜 Aluminium conductor, XLPE insulated and PVC sheathed power cable
|
YJY
|
銅芯交聯聚絕緣氯護套電力電纜 Copper conductor ,XLPE insulated and PEsheathed power cable
|
YJLY
|
鋁芯交聯聚絕緣氯護套電力電纜 Alumimium conductor ,XLPE
|
|
產品介紹:高壓交聯電纜產品具有傳輸容量大,工作溫度,不受落差的,安裝敷設方便等特點,廣泛應用于工礦企業和城市電網中。高壓交聯電纜主要用于電力、建筑、工礦、冶金、交通等部門的動力、照明輸配電,由于聚是電絕緣性能好的塑料,加上經過高分子交聯后成為熱固性材料,因此其電性能好,機械性能和耐熱性好。近二十年來,已成為中、高壓電纜的主導品種,產品適用于6——35KV的各個電壓級中它可分為:YJV-交聯聚乙稀絕緣聚氯護套電力電纜,YJV22-交聯聚絕緣鋼帶鎧裝高壓電纜,YJLV-交聯聚絕緣鋁芯鋼帶鎧裝高壓電纜。
執行:GB/T12706-2002
使用特性
· 工頻額定電壓U0/U為6kv/10kv~26/35kv。
· 電纜導體的高允許工作溫度:90℃。
· 短路時(長時間不超過5s)電纜導體的高溫度不超過2500C。
· 電纜敷設時溫度應不低于00C。
· 電纜彎曲半徑:三芯電纜不小于電纜外徑15倍;單芯電纜不小于電纜外徑20倍。
電纜額定電壓的選擇
· 電纜的額定電壓應適合于電纜的運行狀況,用U0/U(Um)kv表示。
U0-電纜設計用的導體對地或金屬屏蔽之間的額定工頻電壓;
U-電纜設計用的導體間的額定工頻電壓;
Um-設備可承受的“高電壓”的大值。
產品參數:
導體標稱截面
|
絕緣
厚度
|
護套
厚度
|
電纜近似外徑
|
電纜近似重量
|
20℃
導體
|
電纜載流量
|
短路電流
|
直流
電阻
|
在空
氣中
|
直埋土壤中
|
導 體
|
屏蔽層
|
銅帶
|
銅絲
|
mm 2
|
mm
|
mm
|
mm
|
kg/km
|
Ω/km
|
A
|
A
|
KA
|
KA
|
KA
|
3×25
|
3.4
|
2.4
|
48
|
3190
|
0.727
|
120
|
125
|
3.69
|
2.958
|
-
|
3×35
|
3.4
|
2.5
|
50
|
3731
|
0.524
|
140
|
155
|
5.15
|
2.958
|
-
|
3×50
|
3.4
|
2.6
|
53
|
4396
|
0.387
|
165
|
180
|
7.31
|
2.958
|
-
|
3×70
|
3.4
|
2.7
|
57
|
5198
|
0.268
|
210
|
220
|
10.2
|
2.958
|
-
|
3×95
|
3.4
|
2.9
|
62
|
6350
|
0.193
|
355
|
265
|
13.8
|
2.958
|
-
|
3×120
|
3.4
|
3
|
65
|
7257
|
0.153
|
290
|
300
|
17.4
|
2.958
|
-
|
3×150
|
3.4
|
3.1
|
69
|
8383
|
0.124
|
330
|
340
|
21.7
|
2.958
|
-
|
3×185
|
3.4
|
3.2
|
72
|
9741
|
0.0991
|
375
|
380
|
26.7
|
2.958
|
-
|
3×240
|
3.4
|
3.3
|
78
|
11854
|
0.0754
|
435
|
435
|
34.6
|
3.301
|
-
|
3×300
|
3.4
|
3.4
|
84
|
14861
|
0.0601
|
495
|
485
|
43.1
|
3.301
|
-
|
|
|
|
|
|
|
|
|
|
|
|