SGU
|
AC
|
Smart Grid Unit, med fiber forbundne CT's (isoleret)
|
1A - 400A
|
|
|
SGU
|
AC
|
Smart Grid Unit, med lednings forbundnene CT's
|
1A - 500A
|
Control relays
|
|
Current, Single Phase
|
|
|
IMCA
|
AC-DC
|
Multifunction, 12 rages for under or over current in one unit
|
0,5mA - 10A
|
|
|
IDRA
|
DC
|
Low cost, 4 standard currents
|
3 - 16A
|
|
|
ILUA
|
DC
|
Current loop relay
|
4 - 20mA
|
|
|
ILUB
|
DC
|
Current loop relay w. precision adjustment
|
4 - 20mA
|
|
Current, Single Phase, with through hole for CT
|
|
|
IMAA
|
|
Current, Earth leakage and Differential current
Multifunction with 12 current ranges in one unit
|
5mA - 100A
|
|
|
IADA
|
AC
|
Current detecting relay with delayed drop out. 12VDC supply
|
9 - 16VDC
|
|
|
DDCA
|
DC
|
Current, Earth leakage and Differential current. 6 current settings
|
5 - 200mA
|
|
|
DDCB
|
DC
|
Current, Earth leakage and Differential current. 6 current settings (Ext. coil)
|
5 - 300mA
|
|
|
DDEA
|
DC
|
Current, Earth leakage for DC unearthed systems, Asym leakage
|
0,2 - 30mA
|
|
|
DDEB
|
DC
|
Current, Earth leakage for DC unearthed systems, Asym & Sym leakage
|
0,2 - 30mA
|
|
Current, single Phase, with voltage compensated setpoint
|
|
|
IUAB
|
AC
|
AC current relay, monitoring up to 10 loads, error if one or more fails
|
0,2 - 2,5A
|
|
Voltage, Single Phase
|
|
|
UMCA
|
AC-DC
|
Multifunction, 11 ranges in one
|
50mV - 500V
|
|
|
UAWA
|
AC
|
Window Voltage relay. Individual low & high voltage setting
|
100 - 415V
|
|
Voltage, Single Phase, incl. frequency control
|
|
|
UFWA
|
AC
|
Window voltage & frequency relay. Individual low & high voltage setting
|
100 - 415V
|
|
Voltage, 3 phase 4 wire
|
|
|
PNDA
|
AC 4w
|
Phase under voltage & phase sequence
|
100 - 415V
|
|
|
PNDI
|
AC 4w
|
Phase under voltage & phase sequence with true time delay
|
100 - 480V
|
Battery Control relays
|
|
|
BMCA
|
DC
|
Battery low voltage monitoring relay. For 12V, 24V, 48V & 110V batteries.
Replacement for BVCA, BVCB, BVCC
|
8 - 80V
|
|
|
BMCD
|
DC
|
Battery high/low voltage monitoring relay. For 12V, 24V, 48V & 110V batteries
Replacement for BVCD, BVCE, BVCF
|
8 - 180V
|
|
|
BMWB
|
DC
|
Universal DC voltage relay. Individual Low & High voltage plus hysteresis setting
|
12,5 - 340V
|
|
|
BVSA
|
DC
|
Battery symmetry monitoring relay
|
12, 24 and 48V
|
|
|
BMSA
|
DC
|
Battery symmetry monitoring relay with digital setting and display
Symmetry setting: 1 to 20% of cell voltage
|
24 - 256V
|
|
|
BRIA
|
DC
|
DC ripple relay. Setting: 0.4 – 6.4% ripple
|
18 - 340V
|
Phase, Neutral & Ground monitoring. 3, 4 or 5 wire
|
|
|
PMSA
|
AC
|
RMS Neutral to Ground plus RMS Phase to Neutral or RMS Phase to phase
|
50 - 830V
suppl.: 18-288V
|
Phase failure relays, 3 or 4 wire
|
|
Voltage and asymmetry
|
|
|
PADA
|
AC 3w
|
Unbalance & Balanced under & over voltage
|
100 - 480V
|
|
|
PADI
|
AC 3w
|
PADA with true time delay
|
100 - 480V
|
|
|
PANA
|
AC 4w
|
PADA with test for Neutral
|
100 - 480V
|
|
|
PANI
|
AC 4w
|
PADA with test for Neutral and true time delay
|
100 - 480V
|
|
Voltage and asymmetry + phase rotation
|
|
|
PAHA
|
AC 3w
|
Phase rotation w. 2 relays, Unbalance & Balanced under & over voltage
|
100 - 480V
|
|
|
PAHI
|
AC 3w
|
PAHA with true time delay
|
100 - 480V
|
|
|
PAMA
|
AC 4w
|
PAHA with test for Neutral
|
100 - 480V
|
|
|
PAMI
|
AC 4w
|
PAHA with test for Neutral and true time delay
|
100 - 480V
|
|
Voltage and asymmetry + Frequency
|
|
|
PAFA
|
AC 3w
|
Frequency 50, 60 and 400Hz, Unbalance & Balanced under & over voltage
|
100 - 480V
|
|
|
PAGA
|
AC 4w
|
PAFA with test for Neutral
|
100 - 480V
|
|
Voltage and asymmetry + Frequency + phase rotation
|
|
|
PAFB
|
AC 3w
|
PAFA with test for Phase rotation
|
100 - 480V
|
|
|
PAGB
|
AC 4w
|
PAFA with test for Phase rotation and Neutral
|
100 - 480V
|
Load monitoring relays
|
|
Power factor Cos Phi
|
|
|
LMCB
|
Ph. Angle
|
Over or Under load. 2, 3 and 4 wire
|
24 - 440V
|
|
Active power
|
|
|
LMWB
|
AC Watt
|
Over & Under load or 2 x Overload. Analogue adjustment. 2, 3 and 4 wire
|
60 - 400V
|
Engine & generator relays
|
|
Starter
|
|
|
ESPA
|
DC
|
Programmable start or pause firs. 1-15 trials
|
9 - 30V
|
|
Starter inhibit
|
|
|
FXAA
|
Freq.
|
Frequency range from 10 to 5120Hz. Transformer, Namur or optocoupler input
|
12V
|
|
|
FAAA
|
Freq.
|
Frequency range from 10 to 5120Hz. Transformer, Namur or optocoupler input
|
24V
|
|
Over speed
|
|
|
FXBA
|
Freq.
|
Frequency range from 10 to 5120Hz. Transformer, Namur or optocoupler input
|
12V
|
|
|
FABA
|
Freq.
|
Frequency range from 10 to 5120Hz. Transformer, Namur or optocoupler input
|
24V
|
|
Starter inhibit and over speed
|
|
|
FRAA
|
Freq.
|
Frequency range from 10 to 5120Hz. Transformer, Namur or optocoupler input
|
12V
|
|
|
FRBA
|
Freq.
|
Frequency range from 10 to 5120Hz. Transformer, Namur or optocoupler input
|
24V
|
|
Synchronizer
|
|
|
SYND
|
AC 2w
|
Synchronization of grid and generators
|
100 - 500V
|
|
|
SYPD
|
Bus 3w
|
Optional 96x96 Panel indicator to SYND
|
Bus 3 wire
|
Isolation amplifiers
|
|
Multi function, Volt and mA input
|
|
|
AISA
|
DC
|
Programmable: 8 input and 8 output volt/mA ranges. Includes power supply
|
24 - 440V
|
|
Multifunction, mV input
|
|
|
AISB
|
DC
|
Programmable: 4 mV input and 8 volt/mA output ranges. Includes power supply
|
24 - 440V
|
|
Multifunction, Volt input
|
|
|
UISA
|
DC
|
Programmable w.16 input volt ranges and, 8 output V/mA ranges. Incl. power supply
|
24 - 440V
|
|
|
UISB
|
DC
|
Programmable w.16 input volt ranges and current loop output. Incl. power supply
|
24 - 440V
|
|
Volt in and current loop out
|
|
|
UIDA
|
DC
|
2 input ranges: 4.8 - 24V and 6 - 30V to current loop
|
4 - 20mA
|
|
Current loop isolator
|
|
|
AITA
|
DC
|
Current loop. 3 loops 4 to 20mA. Loop powered
|
4 - 20mA
|
|
|
AITB
|
DC
|
Current loop. 1 loop 4 to 20mA. Loop powered
|
4 - 20mA
|
Transducers
|
|
Current
|
|
|
IAMA
|
AC
|
Dual range: 1 & 5Aac in to 6 standard V/mA output ranges
|
24 - 440V
|
|
|
IAMB
|
AC
|
Dual range: 1 & 5Aac in to 4 - 20mA current loop out
|
24 - 440V
|
|
Voltage
|
|
|
UAMA
|
AC
|
Dual range: 250 & 500Vac in to 6 standard V/mA output ranges
|
24 - 440V
|
|
|
UAMB
|
AC
|
Dual range: 250 & 500Vac in to 4 - 20mA current loop out
|
24 - 440V
|
|
Frequency
|
|
|
FAMA
|
Freq.
|
Min. & Max. range specified from 1 to 5000Hz. 8 V/mA output ranges
|
24 - 440V
|
|
Power Active
|
|
|
WAAA
|
AC Watt
|
1 - Phase 2 wire. Select from 19 Volt or mA unipolar or bipolar outputs
|
24 - 440V
|
|
|
WABA
|
AC Watt
|
3 - Phase 3 & 4 wire symmetrical load.
|
24 - 440V
|
|
|
WACA
|
AC Watt
|
3 - Phase 3 wire asymmetrical load (Aron coupling)
|
24 - 440V
|
|
|
WADA
|
AC Watt
|
3 - Phase 3 & 4 wire asymmetrical load
|
24 - 440V
|
|
Power Reactive
|
|
|
WRBA
|
AC Watt
|
3 - Phase 3 & 4 wire symmetrical load
|
24 - 440V
|
|
|
WRCA
|
AC Watt
|
3 - Phase 3 wire asymmetrical load (Aron coupling)
|
24 - 440V
|
|
|
WRDA
|
AC Watt
|
3 - Phase 3 & 4 wire asymmetrical load
|
24 - 440V
|
|
Compact Smart Meter incl. Current Transformer, ModBUS
|
|
|
PM-2133
|
AC Watt
|
3 - Phase 3 & 4 wire asymmetrical load
|
10 - 500V
|
|
|
PM-2134
|
AC Watt
|
1 - Phase 4 wire asymmetrical load
|
10 - 300V
|
Design of housing for 35/45/55 and 22,5 mm housing
|
|
|
DEH
|
|
Cabinet drawings
|