              RSD RS-250 頭部CT模體,RS-250頭部彷真CT模體特點:
              擬人化
              被鑄造的Acround頭骨
              檢查重要的物理參數
              提供真實的系統檢查
              理想的培訓
              聚碳酸酯底座的尺寸適用于與縱軸平行或垂直的掃描

              RSD RS-250 頭部CT模體,RS-250頭部彷真CT模體

              A部分: 0.4毫米厚的鋁板設置45°角,測量光束寬度和切片厚度。  
               RS-250 A部分

              RSD RS-250 頭部CT模體,RS-250頭部彷真CT模體

              B部分:劑量測定部分提供患者暴露控制,并在實際患者掃描前檢查異常內部劑量。定制容納TLD與棒或芯片是可用的。  
               RS-250 B部分
              RSD RS-250 頭部CT模體,RS-250頭部彷真CT模體

              C部分:分級大小和放射性的圓柱形腫瘤建立高對比度和低對比度分辨率,并顯示部分光束平均效應。    
              RS-250 C部分
              RSD RS-250 頭部CT模體,RS-250頭部彷真CT模體

              D部分:擬人部分在空氣對比的內耳和骨折的巖骨中提供實際的聽覺小骨。后顱窩小腫瘤被放置在大多數掃描儀難以成像的區域。  

               RS-250 D部分
              RSD RS-250 頭部CT模體,RS-250頭部彷真CT模體

              E部分:人體模型縱軸上1/4英寸直徑的鋁棒,檢查一般對準情況,“干水”給出了一個現實的“噪音檢查”。

              RSD RS-250 頭部CT模體,RS-250頭部彷真CT模體

              CT Head with 5 slices to test all parameters of computerized tomography
              Anthropomorphic
              Molded Around Skull
              Checks Important Physical Parameters
              Provides Realistic System Check
              Ideal For Training
              Polycarbonate Base Dimensioned For Scans Parallel or Perpendicular to Longitudinal Axis
              SECTION A: Aluminum plates, 0.4mm thick, set at a 45° angle, measure beam width and slice thickness.

              SECTION B: The dosimetry section provides patient-exposure controls, and checks on abnormal internal doses before actual patient scans. Customization to accommodate TLD with rods or chips is available.

              SECTION C: Cylindrical tumors of graded sizes and radiodensities establish high and low-contrast resolution and demonstrate partial beam-averaging effects.

              SECTION D: The anthropomorphic section provides actual auditory ossicles in an air-contrast inner ear and a fractured petrous bone. Small tumors in the posterior fossa are placed in an area which most scanners image with difficulty.

              SECTION E: 1/4 Inch diameter aluminum rod on the phantom's longitudinal axis, checks general alignment, and "DryWater" gives a realistic "noise check."

              深圳為爾康科技有限公司 
              聯系人:曾先生 手機
              微信號:13718096482  QQ:215620749
              電話:0755-28896837  15361860065
              網址:www.medicalqc.com 

              在線詢盤/留言 請仔細填寫準確及時的聯系到你!

              • 您的姓名: *
              • 聯系手機: *
              • 固話電話: *
              • 聯系郵箱:
              • 所在單位:
              • 需求數量: *
              • 咨詢內容:
              • 您要求廠家給您提供:
                規格型號 付款條件 產品目錄 最低訂貨量 運送資料 提供樣本 庫存情況 包裝材料
              版權聲明以上所展示的信息由會員自行提供,內容的真實性、準確性和合法性由發布會員負責。機電之家對此不承擔任何責任。 友情提醒:為規避購買風險,建議您在購買相關產品前務必確認供應商資質及產品質量。
              今日最新產品
              PLC精品
              熱門產品

              機電之家網 - 機電行業權威網絡宣傳媒體

              關于我們 | 聯系我們 | 廣告合作 | 付款方式 | 使用幫助 | 會員助手 | 免費鏈接

              Copyright 2025 jdzj.com All Rights Reserved??技術支持:機電之家 服務熱線:0571-87774297

              網站經營許可證:浙B2-20080178


              免费人成激情视频在线看