              PLC企業資訊
                ABB ADVU-63-15-APA
                發布者:weixuan88  發布時間:2024-05-14 09:23:44

                 
                 
                 
                 
                Clearing I2t
                at  
                Voltage
                Breaking
                capacity I1
                Minimum
                breaking
                current I3
                = Imin
                Cold resistance
                R20 (+/-10%)
                Power
                dissipation
                 
                 
                ?56mm, length 367mm
                45DB175V6,3PT G1006118 6 3 A 1 kA2s 63 kA 30 A 245 m? 11 W 1 2 2 kg
                45DB175V10PT H1006119 10 A 1 5 kA2s 63 kA 43 A 180 m? 22 W 1 2 2 kg
                45DB175V16PT J1006120 16 A 2 kA2s 63 kA 54 A 150 m? 53 W 1 2 2 kg
                45DB175V25PT K1006121 25 A 6 kA2s 63 kA 93 A 78 m? 73 W 1 2 2 kg
                45DB175V32PT L1006122 31 5 A 10 kA2s 63 kA 105 A 59 m? 95 W 1 2 2 kg
                45DB175V40PT M1006123 40 A 30 kA2s 63 kA 125 A 33 8 m? 79 W 1 2 2 kg
                45DB175V50PT N1006124 50 A 50 kA2s 63 kA 205 A 26 m? 106 W 1 2 2 kg
                45DB175V63PT P1006125 63 A 100 kA2s 63 kA 280 A 18 4 m? 135 W 1 2 2 kg
                ?65mm, length 367mm
                45DB175V80PT Q1006126 80 A 150 kA2s 63 kA 350 A 15 m? 183 W 1 2 6 kg
                ?88mm, length 367mm
                45DB175V100PT S1006128 100 A 200 kA2s 63 kA 500 A 13 m? 240 W 1 3 5 kg
                45DB175V100PT
                HIGH VOLTAGE FUSE SYSTEM
                EP MERSEN COM 250
                MERSEN reserves the right to change, update or correct, without notice, any information contained in this datasheet 
                Limitor®- PTD Back-up Fuses
                with Controlled  , for German standard VDE 0670 T402
                DIN HV BACK-UP FUSES FOR TRANSFORMERS
                  6 /12 kV, length 292mm
                 
                 
                 
                 
                 
                current
                In
                Clearing I2t
                at  
                Voltage
                Breaking
                capacity
                I1
                Minimum
                breaking
                current I3 = Imin
                Cold resistance
                R20 (+/-10%)