                霍尼韋爾氣體傳感器 MIDAS-E-HFL
                發布者:liding  發布時間:2018-03-02 17:10:00

                霍尼韋爾氣體傳感器 MIDAS-E-HFL

                供應Midas? 氣體偵測器傳感器


                型號:
                Midas Cartridge Detectable Gases
                Gas Name Chemical Formula Range Sensor Part Number
                Ammonia NH3 9-100 ppm MIDAS-E-NH3
                Arsine AsH3 18-200 ppb MIDAS-E-ASH
                Boron Trichloride BCl3 0.72-8 ppm MIDAS-E-HCL
                Boron Trifluoride BF3 0.72-8 ppm MIDAS-E-HFX
                Boron Trifluoride (Low Level) BF3 0.18-2 ppm MIDAS-E-HFL
                Bromine Br2 0.036-0.4 ppm MIDAS-E-BR2
                Carbon Dioxide CO2 0.15-2.0% MIDAS-E-CO2
                Carbon Monoxide CO 9-100 ppm MIDAS-E-COX
                Chlorine Cl2 0.18-2 ppm MIDAS-E-HAL
                Chlorine Dioxide ClO2 0.036-0.4 ppm MIDAS-E-BR2
                Diborane B2
                H6 36-400 ppb MIDAS-E-B2H
                Dichlorosilane H2
                Cl2
                Si 0.72-8 ppm MIDAS-E-HCL
                Difluoromethane** CH2
                F2 16-240 ppm MIDAS-E-XCF
                Disilane Si2
                H6 1.8-20 ppm MIDAS-E-SHX
                Fluorine F2 0.36-4 ppm MIDAS-E-HAL
                Germane GeH4 70-800 ppb MIDAS-E-ASH
                Hexafluorobutadiene** C4
                F6 3-40 ppm MIDAS-E-CFX
                Hydrogen (%LEL) H2 6.5-100% LEL MIDAS-E-LEL*
                Hydrogen (ppm) H2 90-1000 ppm MIDAS-E-H2X
                Hydrogen Bromide HBr 0.72-8 ppm MIDAS-E-HCL
                Hydrogen Chloride HCl 0.72-8 ppm MIDAS-E-HCL
                Hydrogen Cyanide HCN 1.8-20 ppm MIDAS-E-HCN
                Hydrogen Fluoride HF 1.05-12 ppm MIDAS-E-HFX
                Hydrogen Fluoride (Low Level) HFL 0.18-2 ppm MIDAS-E-HFL
                Hydrogen Sulfide H2
                S 3.6-40 ppm MIDAS-E-H2S
                Methane (%LEL) CH4 6.5-100% LEL MIDAS-E-LEL*
                Methyl Fluoride** CH3
                F 8-120 ppm MIDAS-E-XHF
                Nitric Oxide NO 9-100 ppm MIDAS-E-NOX
                Nitrogen Dioxide NO2 1.05-12 ppm MIDAS-E-NO2
                Nitrogen Trifluoride** NF3 3.6-40 ppm MIDAS-E-HFX for 00P, XHF for NP1
                Octofluorocyclopentene** C5
                F8 3-40 ppm MIDAS-E-XCF
                Oxygen O2 0.2-25% v/v MIDAS-E-O2X
                Ozone O3 0.065-0.7 ppm MIDAS-E-O3H
                Ozone (Low Level) O3 0.036-0.4 ppm MIDAS-E-O3X
                Phosphine PH3 110-1200 ppb MIDAS-E-PH3
                Silane SiH4 1.8-20 ppm MIDAS-E-SHX
                Silane (Low Level) SiH4 0.18-2 ppm MIDAS-E-SHL
                Sulfur Dioxide SO2 0.7-8 ppm MIDAS-E-SO2
                Tetra Ethyl Ortho Silicate TEOS 3.6-40 ppm MIDAS-E-TEO
                Tungsten Hexafluoride WF6 1.05-12 ppm MIDAS-E-HFX
                Tungsten Hexafluoride (Low Level) WF6 0.18-2 ppm MIDAS-E-HFL

                 

                Midas H2氫氣氣體探測傳感器MIDAS-S-H2X MIDAS-E-H2X

                Hydrogen ppm (H2)
                MIDAS-S-H2X
                MIDAS-E-H2X
                Midas? sensor cartridges are intended
                for use only with Honeywell Analytics’
                Midas? Gas Detector System. Please
                refer to the Midas? Technical Manual
                for further details.
                Technical Data
                Gas Measured Hydrogen (H2)
                Cartridge Part Number MIDAS-S-H2X 1 year standard warranty
                MIDAS-E-H2X 2 year extended warranty
                Sensor Technology 3 electrode electrochemical cell
                Measuring range (ppm) H2 0 – 1000 ppm
                Minimum Alarm 1 Set Point 120 ppm
                Lower Detectable Limit (LDL) 90 ppm
                Repeatability < ? 5 % of measured value
                Linearity < ? 5 % of measured value
                Response Time t62.5 < 50 seconds
                Sensor Cartridge Life Expectancy ≥ 24 months under typical application conditions
                Operating Temperature 0? to 40?C (32? to 104?F)
                Effect of Temperature < ? 0.17 ppm / ?C (0? to 20?C )
                Zero < ? 0.07 ppm / ?C (20? to 40?C )
                Sensitivity < ? 3 % of measured value / ?C
                Operating Humidity (continuous) 10 – 90 % rH
                Effect of Humidity
                Zero No Effect
                Sensitivity No Effect
                Operating Pressure 90 – 110 kPa
                Effect of Position No effect in typical application
                Long Term Drift
                Zero No Drift
                Sensitivity < ? 10 % of measured value / 6 month
                Calibration Gas Hydrogen (H2)
                Challenge Gas (Bump Test) Hydrogen (H2)
                Warm Up time < 10 minutes
                Storage Temperature 5? to 25?C ( 41? to 77?F)
                The sensor data listed is based on ideal test environment; observed performance may vary based on the actual monitoring system and the sampling conditions employed
                Gas / Vapor Chemical Formula Concentration applied (ppm) Reading (ppm H2)
                Ammonia NH3 100 0
                Arsine AsH3 0.2 0
                Carbon Dioxide CO2 1000 0
                Carbon Monoxide CO 100 150
                Chlorine Cl2 1 0
                Chlorine Dioxide ClO2 1 0
                Hydrogen Cyanide HCN 20 0
                Hydrogen Sulfide H2S 20 4
                Iso Propanol C3H7OH 1100 Yes
                Methane CH4 1% 0
                Nitrogen Dioxide NO2 10 -40
                Ozone O3 0.25 0
                Sulfur Dioxide SO2 5 0
                MDA Scientific has developed a sophisticated range of highly sensitive gas detection equipment, designed to perform in ways that define new gas detection performance levels providing total solutions to protect people, improve production efficiency and reduce costs.
                 
                Midas? is a registered trademark of Honeywell Analytics.
                As with all electrochemical sensor cells, dramatic output changes in reported concentrations can be
                expected under rapidly changing environmental conditions. Please ensure sensors are located in areas not
                prone to sudden changes in humidity and temperature.
                Actual readings may be affected by flow rates (although Midas? automatically controls flow rate within
                specified ranges) and absorption on tubing and other gas path surfaces.
                All sensors are shipped pre-calibrated to traceable national standards. Dependent on actual operating
                conditions and overall exposure to gases, each sensor may not require in field calibration for up to 24
                months subject to any requirements to calibrate from local regulations or site practices.
                Calibration and challenge gases should be from a certified and reliable source.
                Cross Sensitivities
                Each Midas? sensor is potentially cross sensitive to other gases and this may cause a gas reading when
                exposed to other gases than those originally designated. The table below presents typical readings that
                will be observed when a new sensor cartridge is exposed to the cross sensitive gas (or a mixture of gases
                containing the cross sensitive species).

                 